Efficiency | Max. Efficiency(%) | 98.20 | | European Efficiency(%) | 97.10 | PV Input Data | Max. Input Power(W) | 28900 | | Max. lnput Voltage(V) | 1000 | | OperatingVoltage Range(V) | 180~900 | | Max. Input Current(A) | 36/36 | | Max. Short Circuit Current(A) | 42/42 | | Number of MPPT Trackers | 2 | | Number of Strings per MPPT | 2/2 | | MPPT Tracking Efficiency(%) | 99.99 | Battery Data | Battery Voltage Range(V) | 180~700 | | Input Number | 2 | | Max.Charge/Discharge Current(A) | 25/25 | | Max.Charge/Discharge Power(W) | 17000 | | Battery Type | Li-ion/Lead-acid | AC Data(On-grid Interface) | Nominal Output Power(W) | 17000 | | Max. Apparent Output Power (VA) | 18700 | | Max Input Power(W) | 30000 | | Nominal Voltage(Vac) | 380/400V,3L/N/PE | | Nominal Frequency(Hz) | 50/60 | | Max. Output Current(A) | 27 | | Max. Thre- phase Unbalanced Output Current(A) | 37 | | Grid Bypass Current(A) | 50 | | Power Factor | ~1 (0.8 lead to 0.8 lag can be set) | | Total Harmonic Distortion(%) | <3 | AC Data(Off-grid Interface) | Nominal Output Power(W) | 17000 | | Max. Apparent Output Power (VA) | 18700 | | Nominal Output Voltage(Vac) | 380/400V,3L/N/PE | | Nominal Output Frequency(Hz) | 50/60 | | Max. Output Three-phase Apperant Power(VA) | 37 | | Max. Output Single-phase Apparent Power(A) | 8500 | | Peak Output Apparent Power(VA)(60s) | 20400 | | Peak Output Apparent Power(VA)(10s) | 25500 | | On/off Grid switching time(ms) | <10 | AC Output Data(Diesel Gen.) | Nominal Voltage(Vac) | 380/400V,3L/N/PE | | Nominal Frequency(Hz) | 50/60 | | Nominal Input Apparent Power(VA) | 30000 | Protection | PV Reverse Polarity Protection | Integrated | | Overcurrent Protection | Integrated | | Anti-islanding Protection | Integrated | | Short Circuit Protection | Integrated | | Leakage Current Protection | Integrated | | Insulation Protection | Integrated | | Surge Protection | DC Type II / AC Type III | General Data | Operating Temperature Range (°C) | -25~60(>45 derating) | | Operating Altitude[m] | <4000 | | Maximum noise index [dB] | 50 | | Topology | Transtormerless isolation | | Cooling Method | Forced air cooling | | Degree of Protection | IP65 | | Relative Humidity[%] | 0~95, No condensation | | DC Connection Type | Amphenol/Phoenix | | AC Connection Type | Plug in connector | | Interaction | LCD,RS485 | | Cloud Communication | RS485( WIFI/4G optional ) | | BMS Communication | CAN | | Meter Communication | RS485 | | Installation Method | Wall-mounted | | Dimension(W*D*H)[mm] | 505*572*235 | | Weight[kg] | 40 | Certification | Safety Standards | EN 62109-1/-2 | | EMC Standards | IEC/EN 61000-6-1/-3 | | On-grid Standard | AS4777.2:2020,NRS097-2-1:2017,EN 50549-1 for Czech,VDE-AR-N 4105:2018,EN50549-1:2019+AC:2,G98 G99,OVE-R25,EN50549-1:2019 for Poland A&B |
|