Efficiency Max. Efficiency(%) | 98.20 | European Efficiency(%) | 97.10 | PV Input Data Max. Input Power(W) | 13600 | Max. lnput Voltage(V) | 1000 | OperatingVoltage Range(V) | 180~900 | Max. Input Current(A) | 18/18 | Max. Short Circuit Current(A) | 20/20 | Number of MPPT Trackers | 2 | Number of Strings per MPPT | 1/1 | MPPT Tracking Efficiency(%) | 99.99 | Battery Data Battery Voltage Range(V) | 180~700 | Input Number | 2 | Max.Charge/Discharge Current(A) | 25/25 | Max.Charge/Discharge Power(W) | 8000 | Battery Type | Li-ion/Lead-acid | AC Data(On-grid Interface) Nominal Output Power(W) | 8000 | Max. Apparent Output Power (VA) | 8800 | Max Input Power(W) | 16000 | Nominal Voltage(Vac) | 380/400V,3L/N/PE | Nominal Frequency(Hz) | 50/60 | Max. Output Current(A) | 12.7 | Max. Thre- phase Unbalanced Output Current(A) | 17.5 | Grid Bypass Current(A) | 35 | Power Factor | ~1 (0.8 lead to 0.8 lag can be set) | Total Harmonic Distortion(%) | <3 | AC Data(Off-grid Interface) Nominal Output Power(W) | 8000 | Max. Apparent Output Power (VA) | 8800 | Nominal Output Voltage(Vac) | 380/400V,3L/N/PE | Nominal Output Frequency(Hz) | 50/60 | Max. Output Three-phase Apperant Power(VA) | 17.5 | Max. Output Single-phase Apparent Power(A) | 4000 | Peak Output Apparent Power(VA)(60s) | 9600 | Peak Output Apparent Power(VA)(10s) | 12000 | On/off Grid switching time(ms) | <10 | AC Output Data(Diesel Gen.) Nominal Voltage(Vac) | 380/400V,3L/N/PE | Nominal Frequency(Hz) | 50/60 | Nominal Input Apparent Power(VA) | 16000 | Protection PV Reverse Polarity Protection | Integrated | Overcurrent Protection | Integrated | Anti-islanding Protection | Integrated | Short Circuit Protection | Integrated | Leakage Current Protection | Integrated | Insulation Protection | Integrated | Surge Protection | DC Type II / AC Type III | General Data Operating Temperature Range (°C) | -25~60(>45 derating) | Operating Altitude[m] | <4000 | Maximum noise index [dB] | 50 | Topology | Transtormerless isolation | Cooling Method | Forced air cooling | Degree of Protection | IP65 | Relative Humidity[%] | 0~95, No condensation | DC Connection Type | Amphenol/Phoenix | AC Connection Type | Plug in connector | Interaction | LCD,RS485 | Cloud Communication | RS485( WIFI/4G optional ) | BMS Communication | CAN | Meter Communication | RS485 | Installation Method | Wall-mounted | Dimension(W*D*H)[mm] | 505*572*235 | Weight[kg] | 35 | Certification Safety Standards | IEC/EN 62109-1/-2 | EMC Standards | IEC/EN 61000-6-1/-3 | On-grid Standard | AS4777.2:2020,NRS097-2-1:2017,EN 50549-1 for Czech,VDE-AR-N 4105:2018,EN50549-1:2019+AC:2,G98 G99,OVE-R25,EN50549-1:2019 for Poland A&B |
|